This page created: 01/27/2026 07:25:50 AM 

COUNTY: HINDS   (Jackson)                     DATE OF LAST INSPECTION.: 0524
                [Supervisor District 2]
STRUCTURE NUMBER...: SA2500000000413
LOCATION...........: SEC 14 T 6N R 1W  
FACILITY CARRIED...: FLAG CHAPEL RD    
FEATURE INTERSECTED: BRANCH OF BOGUE CHITTO   
FUNCTIONAL CLASS...: URBAN COLLECOTR
BRIDGE OWNER.......: 04 - CITY OR MUNICIPAL HIGHWAY AGENCY
MAIN STRUCTURE TYPE: 119

    CONCRETE BOX BRIDGE

BRIDGE LENGTH.........:    36.1 FT
NUMBER OF SPANS.......: 4
SKEW ANGLE............: 00 DEG
APPROACH ROADWAY WIDTH: 29.9 FT
BRIDGE ROADWAY WIDTH..:  0.0 FT

YEAR BUILT......................: 1958
YEAR OF REHABILITATION OR REPAIR:   

AVERAGE DAILY TRAFFIC: 5,000
BYPASS/DETOUR LENGTH.:  3 MI. 

DECK RATING..........: N - NOT APPLICABLE
SUPERSTRUCTURE RATING: N - NOT APPLICABLE
SUBSTRUCTURE RATING..: N - NOT APPLICABLE
CULVERT RATING.......: 6 - SATISFACTORY CONDITION
CHANNEL RATING.......: 7 - GOOD CONDITION

BRIDGE PROGRAM ELIGLBLITY:     
BRIDGE POSTING...........: 
                           A - OPEN NO RESTRICTIONS