This page created: 01/27/2026 07:25:50 AM
COUNTY: WARREN (Vicksburg) DATE OF LAST INSPECTION.: 1025
[Supervisor District 2]
STRUCTURE NUMBER...: SA7500000000040
LOCATION...........: SEC 13 T16N R 3E
FACILITY CARRIED...: CHERRY ST
FEATURE INTERSECTED: GLASS BAYOU
FUNCTIONAL CLASS...: URBAN COLLECOTR
BRIDGE OWNER.......: 04 - CITY OR MUNICIPAL HIGHWAY AGENCY
MAIN STRUCTURE TYPE: 100
CONCRETE OTHER
BRIDGE LENGTH.........: 54.5 FT
NUMBER OF SPANS.......: 1
SKEW ANGLE............: 35 DEG
APPROACH ROADWAY WIDTH: 19.0 FT
BRIDGE ROADWAY WIDTH..: 20.0 FT
YEAR BUILT......................: 1910
YEAR OF REHABILITATION OR REPAIR: 2010
AVERAGE DAILY TRAFFIC: 638
BYPASS/DETOUR LENGTH.: 1 MI.
DECK RATING..........: 6 - SATISFACTORY CONDITION
SUPERSTRUCTURE RATING: 6 - SATISFACTORY CONDITION
SUBSTRUCTURE RATING..: 6 - SATISFACTORY CONDITION
CULVERT RATING.......: N - NOT APPLICABLE
CHANNEL RATING.......: 5 - FAIR CONDITION
BRIDGE PROGRAM ELIGLBLITY:
BRIDGE POSTING...........:
P - Posted for load
TANDEM AXLE (TONS).................. 16
|